Detail produk:
|
Kondisi: | Asli baru | Jaminan: | 12 bulan |
---|---|---|---|
Istilah pengiriman: | DHL / TNT / UPS / FEDEX dll. | Nama: | Sakelar Batas Honeywell |
Fitur: | Material Padat | Tipe: | Anti Corresion |
Cahaya Tinggi: | saklar batas presisi,saklar batas tertutup |
Ironman Technology Co, LTD
Merek Unggulan:
● MADU MADU ● AB ● OMRON ● SIEMENS ● SCHNEIDER
● ROSEMOUNT ● ABB ● PEMBERITAHUAN ● MTL ● GE ● Dan banyak lagi!
C6097A2310 baru Honeywell Pressure Switch baru dalam stok pengiriman DHL
Lead time: 3-5 hari
Baru dengan garansi satu tahun
APLIKASI
The gas pressure switch C6097A is used to detect the pressure of city gas, natural gas, LP gas or air etc. When the gas pressure changes, the diaphragm of the pressure receiving part detects it and operates the (SPOT) switch to ON/OFF control of the external electrical circuit. Saklar tekanan gas C6097A digunakan untuk mendeteksi tekanan gas kota, gas alam, gas LP, atau udara dll. Ketika tekanan gas berubah, diafragma bagian penerima tekanan mendeteksi dan mengoperasikan sakelar (SPOT) ke ON / OFF. kontrol sirkuit listrik eksternal. These switches are widely used to detect the upper limit or lower limit pressure of gas or air to be supplied to a gas burner, or to detect the clogging of the interlock filter of a burner blower Sakelar ini banyak digunakan untuk mendeteksi batas atas atau batas bawah tekanan gas atau udara yang akan dipasok ke kompor gas, atau untuk mendeteksi penyumbatan filter interlock dari burner blower
INSTALASI
1. Read these instructions carefully. 1. Baca instruksi ini dengan seksama. Failure to follow the instructions could damage the product or cause a hazardous condition. Tidak mengikuti petunjuk dapat merusak produk atau menyebabkan kondisi berbahaya. 2. Check the ratings given in the instructions and on the product to make sure the product is suitable for your application. 2. Periksa peringkat yang diberikan dalam instruksi dan pada produk untuk memastikan produk tersebut cocok untuk aplikasi Anda.
Accurate pressure set point adjustment (stand alone only) (tolerance <3% over total scale) 1. Remove the screw from the test nipple inlet. Penyesuaian titik setel tekanan yang akurat (hanya berdiri sendiri) (toleransi <3% dari total skala) 1. Lepaskan sekrup dari lubang masuk nipple tes. 2. Connect the tube of the pressure measurement device to the nipple (Fig. 1. F). 2. Hubungkan tabung perangkat pengukur tekanan ke puting (Gbr. 1. F). 3. Remove the cover of the pressure switch. 3. Lepas penutup sakelar tekanan. 4. Slowly release pressure of the main gas supply line until the desired value is reached. 4. Lepaskan tekanan dari jalur pasokan gas utama secara perlahan sampai nilai yang diinginkan tercapai. 5. Turn dial slowly until contact 1-3 opens and contact 2-3 closes. 5. Putar tombol perlahan sampai kontak 1-3 terbuka dan kontak 2-3 ditutup. 6. Replace the cover. 6. Pasang kembali penutup. 7. Disconnect the pressure measurement device and replace the screw. 7. Lepaskan koneksi perangkat pengukur tekanan dan pasang kembali sekrup. Checkout Checking cut-off pressure After the installation is completed, continue with the following procedures: 1. Slowly close manual main valve with the burner in operation. Checkout Memeriksa tekanan cut-off Setelah instalasi selesai, lanjutkan dengan prosedur berikut: 1. Tutup katup utama manual secara perlahan dengan burner beroperasi. Shut down should occur when the pressure drops below the set point and the alarm (if connected) should be energized. Shut down harus terjadi ketika tekanan turun di bawah titik setel dan alarm (jika terhubung) harus diberi energi. 2. Re open the manual main valve. 2. Buka kembali katup utama manual. The pressure should rise and exceed the set point value, the burner should start up and the alarm turn off after the reset button is depressed. Tekanan akan naik dan melebihi nilai set point, burner akan menyala dan alarm mati setelah tombol reset ditekan.
Kontak Person: Sales Manager
Tel: +8613510133539