Detail produk:
|
Kondisi: | Asli baru | Jaminan: | 12 bulan |
---|---|---|---|
Istilah pengiriman: | DHL / TNT / UPS / FEDEX dll. | ||
Cahaya Tinggi: | kabel serat optik,mc pdoy22 |
Ironman Technology Co, LTD
Merek Unggulan:
● MADU MADU ● AB ● OMRON ● SIEMENS ● SCHNEIDER
● ROSEMOUNT ● ABB ● PEMBERITAHUAN ● MTL ● GE ● Dan banyak lagi!
HONEYWELL 51204037-015 SET KABEL REV Kabel PLC baru
Lead time: 3-5 hari
Baru dengan garansi satu tahun
External Installation of UCN Taps, Continued Protect taps from physical damage Taps must be protected so that they are not abused by bumping or by exposure to the elements such as water and sunlight. Pemasangan Eksternal dari UCN Taps, Lanjutan Melindungi keran dari kerusakan fisik Keran harus dilindungi agar tidak disalahgunakan dengan menabrak atau terkena elemen-elemen seperti air dan sinar matahari. Allow for routing drop cables to network devices When the UCN taps are installed external to an enclosure containing the network device, the drop cables must be routed into the enclosure. Memungkinkan untuk merutekan kabel jatuhkan ke perangkat jaringan Ketika keran UCN dipasang di luar selungkup yang berisi perangkat jaringan, kabel jatuhkan harus dirutekan ke dalam selungkup. That cable length cannot exceed 50 meters (164 feet). Panjang kabel itu tidak bisa melebihi 50 meter (164 kaki). Allow for redundant cable routes Separate paths for the redundant A and B drop cables should be considered if they are in a hazardous location where they can be damaged. Memungkinkan untuk rute kabel redundan Jalur terpisah untuk kabel drop A dan B berlebihan harus dipertimbangkan jika mereka berada di lokasi berbahaya di mana mereka dapat rusak.
Internal Installation of UCN Taps Drop taps can be mounted in TDC 3000X enclosures There are various methods of installing UCN taps in a network device enclosure, such as an Advanced Process Manager cabinet or the cabinet containing a Network Interface Module (NIM). Instalasi Internal UCN Taps Drop taps dapat dipasang di TDC 3000X enclosure. Ada berbagai metode pemasangan UCN taps di enclosure perangkat jaringan, seperti kabinet Advanced Process Manager atau kabinet yang berisi Network Interface Module (NIM). Special tap mounting brackets are available in a kit that includes the UCN taps. Kurung pemasangan keran khusus tersedia dalam kit yang menyertakan keran UCN. Preinstalled taps and drop cables The cabinets containing the network device also can be ordered with the taps and drop cables already installed. Tap dan drop kabel yang sudah dipasang sebelumnya Lemari yang berisi perangkat jaringan juga dapat dipesan dengan keran dan drop kabel yang sudah terpasang. UCN taps installed on sides of PM/APM cabinet Figure 5-3 shows the installation of the UCN taps on the brackets attached to the center cross members at the right and left sides of the Process Manager or the Advanced Process Manager cabinet. Keran UCN dipasang pada sisi kabinet PM / APM Gambar 5-3 menunjukkan pemasangan keran UCN pada braket yang terpasang pada anggota lintas tengah di sisi kanan dan kiri dari Process Manager atau kabinet Advanced Process Manager. UCN trunk cable A connects to the left side trunk cable tap and trunk cable B connects to the right side trunk cable tap. Kabel trunk UCN menghubungkan ke ketuk kabel trunk sisi kiri dan kabel trunk B menghubungkan ke ketuk kabel trunk sisi kanan.
Kontak Person: Sales Manager
Tel: +8613510133539